Panel seal S90

Soft seal for 90 min. fire resistance

Panel seal for wall and floor/ceiling penetrations, designed for the protection of both single and bunches electrical lines and cables (including optical fibre cables) - without restrictions imposed on each cables overall conductor cross-section - as well as of their supporting structures (cable trays and ladders) made of steel, aluminium or plastics.

  • Pressure resistance test up to ± 5500 Pa
  • Application in all fire-rated walls (masonry, concrete, aerated concrete, lightweight partitions 100mm), max. seal size 1300 x 2000 mm (W x H)
  • Ceilings (concrete or aerated concrete 150 mm), max. seal size B=800 mm, L=∞

Panel seal S120

Soft seal for 120 min. fire resistance

Panel seal for wall and floor/ceiling penetrations, designed for the protection of both single and bunches electrical lines and cables (including optical fibre cables) - without restrictions imposed on each cables overall conductor cros-section - as well as of their supporting structures (cable trays and ladders) made of steel, aluminium or plastics.

  • Walls (masonry l concrete l aerated concrete ≥ 120 mm); max seal size: H=2000 mm, W=1200 mm
  • Lightweight partition ≥ 125 mm; Max. seal size: H = 2000 mm, W = 700 mm
  • Ceiling (concrete or aerated concrete ≥ 195 mm); Max. seal size: B = 400 mm, L = ∞

Mortar seal S90

Fiber-free sealing system for cables made of special mortar for 90 min. fire resistance

Special morter sealing system for carrying cables of all different types, cable bundles and cable trays in solid walls and ceilings. 

  • Close to fire and fumes
  • Temperature depleting
  • Closes off
  • Spill-resistant

Mortar seal S120

Fiber-free sealing system for cables made of special mortar for 120 min. fire resistance.

Special mortat sealing system for carrying cables of all different types, cable bundles and cable trays in solid walls and ceilings.

  • Close to fire and fumes
  • Temperature depleting
  • Closes off
  • Spill-resistant

Pillow seal S90

Cushion seal of wall and ceiling ducts for sealing off individual or bundled electric cables and cables of all types, including optical fibers. Without limiting the overall conductor cross-section of the individual cable and its supporting structures (cable trays, platforms, ladders) made of steel, aluminium or plastic pipes ≤ 15 mm.

  • Fire resistance class S90
  • Close to fire and fumes
  • Closes off
  • Reusable
  • Especially flexible
  • Dust-free installation